P602 series t54 point type heat detectorexproof product sheet. The heat detector is mounted via 4 off 9mm exd version or 4 off 7mm exem and exia versions fixing holes in feet on the base of the unit. Autronica also offers exn and exia heat detectors that are designed to be used in high risk applications. Fenwal bei lico, daf, detectafire, series 27000, series. An alarm signal is only enabled in the detector once the processor is satisfied that an actual fire has been detected. The 5600 series consists of both single and dualcircuit. Dec 05, 2017 an hst user learning how to position the heat detector tester to fit in a tight area noisy area. The t54b can be used in environments with ambient temperatures up to 200c and, being hermetically sealed, is impervious tomost contaminants. The latest line of fenwal smoke detectors offers exactly what todays demanding customer is seeking.
Detectafire thermal detectors can be used with clarkes consoles or as a stand alone detector. The t54b is suitable for use in areas with explosive atmospheres. Basically, the rateofrise element consists of an air chamber, a flexible metal diaphragm and a moistureproof, troublefree vent which is. The fenwalnet 6000 is the first fenwal protection systems product that accessible over the internet. T54b probe type heat detector i n f o r m a t i o n s h e e t description the t54b type e heat detector is a sealed stainless steel tubular device operating on a principal of differential coefficients of expansion. Accepts fenwal daf 27121, 28021, 27121, 28020 rate compensated heat detectors. Kidde fenwal smoke detectors choose topquality fire. The need for replacement is indicated when the center disk has fallen free from the detector. A slow rate fire figure 2 will heat the shell and struts together.
A smoke detector is a device that senses smoke, typically as an indicator of fire. No agent, representative, dealer, or employee of the company has the authority to increase. Fenwal detectafire series 27000 heat detector the fenwal detectafire series 27000 are precision temperature sensors. Series 17343 fire and overheat detectors fenwal controls. The 5600 series heat detector is intended for use in property protection applications, or for non lifesafety installations where smoke detection is not practical or appropriate. About us tyco simplexgrinnell provides a comprehensive array of fire alarm, fire sprinkler, fire suppression, integrated security, emergency communications, sound, and. Mount detector to a suitably listed fitting in accordance with national electric code andor local authority having jurisdiction. Kidde fenwal advanced psd7157 and psd7157d photoelectric smoke detectors respond to a broad spectrum of both flaming and smoldering fire conditions. Heat detector spacing reduction based on ceiling height. Heat detectors from the sseries are designed to be used in applications where high sensitivity is required. Hst series heat detector tester operation manual hst series heat detector tester configuration guide hst series brochure rate compensated heat detector testing rate compensated heat detector test method comparison testing model 17343124 heat detectors testing for heat detector rate compensation. The fenwal detectafire series 27000 are not position sensitive so they can be mounted horizontally and vertically, depending on. Analaser ii detector with optional display module figure 2. Temperature heat detector uses a thermistor as a temperature sensor with a linear resistance characteristics.
This includes making our order, service and delivery process a seamless and hasslefree experience. Find here heat detectors, heat alarm suppliers, manufacturers, wholesalers, traders with heat detectors prices for buying. Fire suppression systems bulk clean agent gas fire alarm control panels kidde fenwal heat detector fire. Effective kidde fenwal smoke detectors available for sale at very reasonable price. Protect your home and business with top quality heat detectors. Pn edw302epm194 conventional fire alarmsheat detectors, rate compensation302 series edwards series 302 heat detectors are suitable for use in indoor and outdoor environments and explosive atmospheres. The fenwal detectafire series 27000 are not position sensitive so they can be mounted horizontally and vertically, depending on the applications and the installation requirements. Fenwal 271210 detectafire heat detector alarm sensor 12in npt d584956. I am not sure about the reason for a heat smoke detector to cover an oil filled transformer. The thermotech 302 series rateanticipation heat detectors operate within a controlled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise.
The sd851te photoelectric smoke thermal detector incorporates an optical chamber and a thermal element, which in turn are continually monitored by an on board processor by using algorithms developed specifically for the unit. The t54b is available in either normally open or normally closed contact configurations. The builtin microprocessor with analogtodigital convertor processes the input signal from the thermistor determine the fire condition. Nonetheless, the fenwal detectafire units should be periodically checked for proper operation. Uk distributor of heat detectors from fenwal controls hawco. The detector initiates an alarm in response to both rapid rateofrise conditions increases in excess of 15f per minute and fixed heat 5f. Kidde orion xt is a powerful early warning detection system that. For lifesafety installations, smoke detectors must be used, in lieu of, or in addition to heat detectors.
Amoxil dosage for kidney infection official online drugstore. The 700 series conventional photoelectric smoke detector is an interchangeable head and base detector with a lightscattering optical sensor that provides outstanding stability and excellent response to a wide range of fires. Explosionproof smoke detector conventional initiating devices df60483. Constructed from stainless steel, the tyco t54b is a rugged heat detector that can be used to detect fires in the harshest of environments.
Contact control fire pros today to get a quote for honeywell gas detection and other fire alarm devices from renowned brands. Detection during the incipient stage allows time for corrective action, possibly preventing an. Here it is used in combination with a sprinkler system to detect overheat and actuate an alarm. The heat detector has been designed to operate in any attitude removingreplacing the cover. Amerisponse the source for all your access control, audio and video, central vacuum, fire alarm, hardware and tools, home automation, intercoms, security systems, nurse call. This enables the heat detector to communicate an alarm to the central control panel prior to reaching its fixed set point for high rates of rise, providing a timely response to both rapid and slow. Fire detection and alarm system principle is based on three devices. Heat detector, other fire detectors, radiant energy. Browse our site for a noobligation quote for kidde fenwal smoke detectors and other fire alarm devices from reliable companies. Smoke and heat detector system integrated circuits and reference.
There are 12 heat detectors in the series 65 range designed to suit a wide variety of. Interchangeable nimh battery batons and a fast battery recharger enable testing all day with a cable free professional device. Testing a 190 degree f fenwal 27121 rate compensated heat detector using hst series heat detector tester model hstaalo fenwal rate compensation heat detectors are. The 700 series conventional photoelectric smoke detector is an interchangeable head and base detector with a. The heat detector uses a state of the art heat element combined with an. Detectafire daf detectors are the heart of many fire protection systems. Model t301 normally closed contact heat detector, 275f, 5c. Fenwal heat detector test demo 2 skinner innovations. Hst series heat detector test kits skinner innovations. The detector shave advanced solidstate, lowvoltage, surfacemount circuitry and are designed for 2wire and 4wire installation using the appropriate detector. Detectafire units by fenwal controls have met with wide acceptance because they are designed with rate compensation. At the set point, the unit will trigger, actuating the alarm or releasing the extinguishant. The ultra analaser ii detector has a sensitivity range of 0. The attractive, functional design lends physical protection of the unit while making it suitable for residential, commercial, industrial, mercantile and public buildings, institutions and ships in nonhazardous locations those classified as ordinary under the national electric.
Replace detectafire after any fire or heat related event, any mechanical damage, or after 10 years of continuous service. This manual applies to the detector with electronics version 1. Instruction manual continuous fire and overheat detection systems for industry cfd installation, operation and maintenance the contents of this manual are proprietary to fenwal and are submitted in confidence. The fenwal analaser ii is one thousands times more sensitive than a conventional detector. The marine grade alloy exd version is suitable for use offshore or onshore, where light weight combined with corrosion resistance and strength is required. When used with a console, a interface device id is necessary to link the heat detector to the console. Wireless smoke alarms with sub1ghz simplelink wireless mcu rev. These encompass electric lighting and power systems, heating and air conditioning equipment, heat producing conservation and maintenance activities, and. The mp series is a standard thermoflex single circuit, normally. The lhs linear heat sensor cable is a flexible, durable and costeffective fixedtemperature fire detector, suitable for protecting a wide range of commercial and industrial fire applications. Fenwal heat detectors kidde fenwal heat sensor cable notifier addressable detectors fsc851 intelliquad multicriteria detector notifier fsv951 early warning detector notifier.
The leds shall continuously indicate the operating condition of the detector. Constructed from stainless steel, the t54b is an extremely rugged heat detector that can be used to detect fires in the harshness of environments. Model 721ut photoelectric detectors include integral fixed temperature and rateofrise heat detectors. In areas, such as kitchens, where a degree of smoke and steam are normal and safe, a heat detector the perfect device for protecting you from unsafe rises in temperature. Linear heat sensor cable posted on july 16, 2015 by safetysys. Kidde fenwal smoke detectors choose topquality fire alarm. Information such as current events, event logs, and smoke detector sensitivities can be accessed using any standard web browser when the intelligent communications module icm is installed with the fenwalnet 6000 system. The hd1 heat detector has been designed for use in the offshore and onshore oil, gas and petrochemical industries. Effective honeywell gas detection for sale at an attractive price. Assembly of the hst series heat detector tester for probe type, fire alarm heat detectors, thermal switches, rate compensation, rate of rise, and fixed temperature heat detectors. Open contacts detectors, in which the connectivity is modified. The world standard in mechanical heat detectors a detectafire detector is the heart of many fire protection systems. B1 f920 general the pyrotector model 303003 explosion proof smoke detector is a sensitive yet rugged protection device that is designed for use in hazardous industrial and commercial locations.
Detectafire detectors are designed for long life expectancy, however due to various field conditions it is required that the detectors be tested annually per nfpa guidelines or local fire codes. Horizontal heat detectors are designed for locations where appearance is a factor. These detectors will respond to a broad range of flaming and smoldering fire conditions. The photoelectric smoke detector can be used for openarea application as well as duct mounting applications with air velocity of 2000ftmin up to 4000ftmin.
The t54b can be used in environments with ambient temperatures up to 280 degrees, and being hermetically sealed, is impervious to most contaminants. Comprising a fenwal ratecompensated detector with allstainless steel external construction, mounted to either a type sm87 marine. System sensor warrants its enclosed heat detector to be free from defects in materials and workmanship under normal use and service for a period of three years from date of manufacture. Typical ceiling installation of a horizontal detectafire model. Fenwalnet control units are backwardcompatible with the installed base of smartone initiating and control devices, preserving your investment in fenwal fire suppression system products that you have acquired over the years. Fenwal believes this data to be accurate, but it is published and presented without any guarantee or warranty whatsoever. System sensor is a global manufacturer of fire and life safety devices, in smoke detection, carbon monoxide detection, and notification technology. Hst fenwal heat detector tester standard heating youtube. The oil is normally a non combustible under definition of nfpa product and transformers under many circumstances blow up at which point smoke detectors would be meaningless. The series 65 heat detector monitors temperature by using a dual thermistor network.
The tsd1 multisensor detector can detect the early stages of fire development when there is some visible smoke andor temperature rise. Fenwal controls strongly suggests selecting a daf detector with a temperature setting a minimum of. Certified data in support of use in safety functions. Unlike passive smoke detectors that wait for smoke to pass through them, the analaser ii is an active airsampling system that draws the particles into its laser particle counter detection chamber and checks the particles for traces of smoke. System sensor makes no other express warranty for this heat detector. Fenwal detectafire units are ul and ulc listed and fm approved as fire detection thermostats close on temperature rise and as releasing devices open on temperature rise. Thousands of these detectors are in use controlling the release of clean agents, co2, water, or dry chemicals. Lavastica international can supply a wide range of autronica heat detectors worldwide, within a short period of time.
Heat detectors experts in fire and security installations. Detectafire fire and overheat detectors fenwal controls. By ignoring transient warm air excursions, the detectafire. The hd1 heat detector uses a fenwal heat detector contact which is encased in either a marine grade alloy sm87 enclosure or a jb10 grp corrosion free enclosure. Heat detectors are often used inside a bag house for fire protection and are set to activate a deluge valve. We can supply a wide range of autronica heat detectors, autronica spare parts and other autronica equipment such as input and output units and level switches worldwide. Lhs is a small diameter cable capable of detecting heat from a fire read more. Neither the manual nor any part thereof may be disclosed to others or used for purposes other than the maintenance of fenwal equipment. Nfpa 241 standard for safeguarding construction, alteration, and demolition operations impacts on fire alarm systems and installation contractors eric m. Fenwal controls supply globally approved controls for gas ignition, temperature control and fire and overheat detection. Designed and tested under extreme conditions of heat, cold and humidity, u.
The fixing holes have been designed to accept m8 exd version or m6 exeexi versions screws or bolts. Kidde fenwal disclaims any liability for any use that may be made of the data and. Psd7152 models are smart photoelectric smoke detectors. These highly reliable devices have been a standard for over 65 years. Hst series heat detector test kits fenwal detectafire rate compensation heat detectors. T54b probe type e heat detector fire systems products. Fenwal 271210 detectafire heat detector alarm sensor 12in.
Jan 24, 2017 fire detection and alarm system principle. Technical manual for the heat detector hd1 exd iic. Installation and maintenance instructions 5600 series heat. Each smartone detector has the ability to analyze data and make decisions based on its programmed need. George andrew darby patented the first european electrical heat detector in 1902 in birmingham, england. Properly installed and applied, the detectafire offers reliable, economical performance. This provides a unique advantage over both fixed temperature and rateofrise types of detectors because only the detectafire unit accurately senses the surrounding air temperature regardless of the fire growth rate. The detector is designed to operate effectively with both slow smol.
The hd1 heat detector has been designed for use in flammable atmospheres and harsh environmental conditions. Amerisponse the source for all your access control, audio and video, central vacuum, fire alarm, hardware and tools, home automation, intercoms, security systems, nurse call, paging and video security needs. A heat detector is a fire alarm device designed to respond when the convected thermal energy. Kidde fenwal smartone devices choose reliable fire alarm. The fenwal models cpd7054 and cpd7054d ionization smoke detectors shall have two red leds located diametrically opposite each other so as to allow 360degree viewing. These detectors are available in either 5f or 194f ratings. Class ii, groups e, f and g 271200 271210 280210 note.
This unit can be used in environments of very high temperatures and is recommended as alarm device to sense overheat or fire to alert supervisory staff to initiate appropriate measures to counteract the condition. Fire detection for oil filled transformers nfpa fire. An hst user learning how to position the heat detector tester to fit in a tight area noisy area. Series 27100, 28000 vertical detectafire units installation instructions 12. Kidde fenwal recommends that standard 4inch octagonal outlet boxes be used to mount detectors. Hst fenwal heat detector tester standard heating duration. The combination of optical and heat detection provides a faster response to real. If the temperature exceeds the threshold value, or the rate of temperature rise exceeds the. Due to our worldwide network and large stock, we are able to deliver the equipment in a short period of time against competitive prices. Fenwal heat detectors kidde fenwal heat sensor cable notifier addressable detectors fsc851 intelliquad multicriteria detector notifier fsv951 early warning detector notifier conventional detectors explosion proof smoke detector vesda osid fsosiria.
234 779 332 1392 602 1352 1522 132 816 1509 1379 46 1081 637 1436 1489 1170 97 1067 1050 1519 1037 1129 1294 1466 66 1114 520 563 157 898 537 342 447 370 895 308 349 224 475 1353 52